Unit 9, 103-107 Keira Street, WOLLONGONG NSW 2500 02 4200 4593

PRODUCTS
INSULWALL – Insulated Panel for walls

PRODUCTS

INSULWALL – Insulated Panel for walls

InsulWall is a load bearing insulated wall panel, developed in conjunction with BlueScope Steel to offer builders and home owners a simple ‘all-in-one’ product. This walling product is engineered to take the difficulty and inaccuracy out of home construction.

InsulWall® Benefits

  • No frame required, load bearing walling.
  • Purpose designed with unique BlueScope® Steel skin for the application of paint and render coatings.
  • Lightweight construction.
  • High Performing Insulated Core.

Technical Data

Panel Specifications

WIDTH: 1200MM
STEEL SKIN THICKNESS: 0.6mm (standard)
CORE MATERIAL: Standard core EPS SL grade, other core types available
PANEL THICKNESS OPTIONS: 90mm & 140mm

Acoustic Properties Rw value for InsulWall® is 24–25.
Refer Bondor® for your specific application.

1200mm
90 & 140mm
0.6mm (standard)
Standard core EPS SL grade, other core types available

Panel External Coating

External coating will be strictly to the guidelines as per DuSpec Specification Sheet (Exterior) (issue 2 dated 19/01/2010) using Dulux AcraTex Coventry Coarse for InsulWall® by Bondor.®

Panel Internal Coating

Internal coating will be strictly to the guidelines as per DuSpec Specification Sheet (Interior) (issue 2 dated 19/01/2010) Dulux Acratex Wash and Wear 101 Advanced L/G for broad wall and Dulux Acratex Wash and Wear Kitchen and Bathroom L/G for wet areas to InsulWall® by Bondor.®

Technical Data

Mass (kg/m2)
11.8
12.5
U value (W/m2K)
0.43
0.27
R value (m2K/W)
2.35
3.69

Wind Loading Non-Cyclonic

N2
5.4
N3
4.2
N4
3.6

Early Fire Hazard Properties AS1530.3 Indices

Ignitability
0
Spread of Flame
0
Heat Evolved
0
Smoke
2–3

Cyclonic

C1
3.6
C2
3.0
Note: For engineering assumption and criteria refer to Bondor® technical support.

Acoustic Properties

Rw value for InsulWall® is 24–25. Refer Bondor® for your specific application

Further information is available in the technical manual including:
  • Bracing capacity
  • Axial load
  • Support of cupboards and bracket loading